丰满人妻一区二区三区无码AV,丰满少妇人妻HD高清大乳在线,丰满少妇人妻无码,丰满熟妇乱又伦在线无码视频

首頁 Home Product Veterinary Drug Residues Lincomycin ELISA Test Kit

Lincomycin ELISA Test Kit

Analyte:Antibiotic Residue

Samples:Liquid milk (raw milk,condiment, fortified milk, reconstituted milk, milk beverage)

Specification
96 Test/Kit
Product introduction
Summary

Lincomycin is a narrow-spectrum antibiotic of the lincosamide class, which can inhibit the synthesis of bacterial protein. The bacteria have partial cross-resistance to this product and other macrolide antibiotics. Lincomycin may cause liver damage, allergic reactions and cardiovascular reactions. After being metabolized by dairy cows, it may remain in milk samples.

This kit is a drug residue detection product developed by ELISA technology. Compared with instrumental analysis technology, it has the advantages of fast, simple, accurate and high sensitivity. The operation time is only 45 minutes, which can minimize work intensity and operating errors.


Intended Use

The Lincomycin ELISA Kit is intended for the quantitative analysis of lincomycin in commodities such as liquid milk (raw milk, modified milk, reconstituted milk, fermented milk, nutritionally fortified milk, milk-containing beverages, etc.).



Available Products

P/N? ? ??Sensitivity? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?Sample? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??
SC00530.5μg/kg? ? ? ? ? ? ?Liquid milk (raw milk,condiment, fortified milk, reconstituted milk, milk beverage)
SC00540.5μg/kg? ? ? ? ? ? ?Honey


Precautions
1. Adhere to the instructions of test procedures. Do not run more than 8 tests at one time. 2. Store test kits at 2-8?C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. The sample to be tested must be a homogeneous liquid which cannot be agglomerated, fermented, rancid precipitated, etc., and cannot be colostrum. 6. Avoid direct sunlight and direct blows during testing. 7. Do not re-use pipette tips, test strips or microwells. 8. The unsealed microwells should be used within 1 hour. 9. Do not take tap-water, distilled water or deionized water as the negative control. 10. This test method is just used for rapid screening purpose, if positive results are occurred, please verify them by a quantitative method. 11. Considering that all materials, containers and devices exposed to the sample are contaminated with harmful substance,please wear protective gloves and safety glasses while using the kit. 12. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 13. Any problem encountered during usage, please contact with the supplier.
More Products
Leaving a message