首頁(yè) Home Product Biotoxin Fumonisins Quantitative Rapid Test Kit

Fumonisins Quantitative Rapid Test Kit

Analyte:Mycotoxin

Samples:Grain,feed raw material,some finished feed products.

Specification
96T/Kit
Product introduction
Summary

Fumonisin is one of the mycotoxins produced by F. Moniliforme. And has 28 derivatives. FB is the most universal one of the derivatives, which mainly contaminate corn and their products. FB has a toxin effects to animals because of its powerful toxicity. As study shown that FB can cause the Leukoencephalopathy softening syndrome of horses and Pulmonary edema syndrome of pigs and can also induce human esophageal cancer, liver cancer, gastric cancer and other diseases, so it poses a threat to husbandry and human health.

Intended Use

The kit is a one-step lateral flow immunochromatographic assay that determines a quantitative level for the presence of Fumonisins and is intended for use in grains, feed materials and feed products. This method is suitable for the rapid on-site test.

Available Product

P/N? ? ? ? ? ? ? ? ? ? ? ? ?Sensitivity? ? ? ? ? ? ? ? ? LOD? ? ? ? ? ? ? ? ? ? ? ? ?Sample

JC0685? ? ? ? ? ? ? ? ? ? -? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 0-60000ppb? ? ? ? ? ? ?Grain,feed raw material,some finished feed products.

Precautions
1. Adhere to the instructions of test procedures. 2. Store test kits at 4-30?C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. Avoid direct sunlight and direct blows during testing. 6. Do not re-use pipette tips, test strips or microwells. 7. The unsealed microwells should be used within 1 hour. 8. This test method is just used for rapid screening purpose; if positive results are occurred,please verify them by a quantitative method. 9. Methanol/ Ethanol are flammable. Caution must be taken in its use and storage. 10. Please avoid direct sunlight or blowing when testing. 11. Do not take tap-water, distilled water or deionized water as a negative control. 12. Considering that all materials, containers and devices exposed to the sample are contaminated with toxins, please wear protective gloves and safety glasses while using a kit. 13. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 14. If the sample extract is too alkaline (pH>9) or acid (pH<5), please adjust the pH value of the sample extract to be 6.0-8.0 by using NaOH or HCl (2.0 mol/L) before dilution. 15. Any problem encountered during usage, please contact with the supplier.